WR Series (Standard)
Size: WR2 to WR40; mount bars from 18 mm; threads M6 x 1,0, M7 x 1,0 and M8 x 1,25 — stainless self-clinching inserts on WR2 to WR8, threaded bar on WR12 to WR40. - Temperature: -100°C to +260°C. - Application: shock and vibration isolation in commercial, industrial and defence equipment to MIL-STD-810, MIL-STD-167, MIL-S-901D, MIL-E-5400, STANAG-042, BV43-44 and DEF-STAN 0755. - Media: all-metal — 302/304 stainless steel rope with 6061-T6 aluminium bars chemical-conversion coated to MIL-C-5541 Class 1A; galvanised, nylon-coated and full stainless options. - Pressure: no pressure rating — selected by load and stiffness (Kv vibration, Ks shock); damping is typically 5 to 15 %. Range STAMP — ITT Enidine Shock Absorbers and Rate Controls catalogue (EN), pp. 105–136

Enidine WR4 Series Wire Rope Isolator Size 800. 10 Loops. Thread / Thread Mounting. Metric
WR2–WR40 -100°C to +260°C
Enidine WR12 Series Wire Rope Isolator Size 700. 8 Loops. Thread / C'sink Mounting. Metric
WR2–WR40 -100°C to +260°C
Enidine WR3 Series Wire Rope Isolator Size 100. 10 Loops. Thread / Thread Mounting. Metric
WR2–WR40 -100°C to +260°C
Enidine WR3 Series Wire Rope Isolator Size 200. 10 Loops. Thread / Thread Mounting. Metric
WR2–WR40 -100°C to +260°C
Enidine WR6 Series Wire Rope Isolator Size 400. 10 Loops. C'sink / C'sink Mounting. Metric
WR2–WR40 -100°C to +260°C